OM 621BCD
6 digit BCD MONITOR
The OM 621BCD model is a 6 digit panel monitor of serial or parallel BCD/BIN signals and monitor of active transformer tapping lead, allowing for projection of transitional status ot servomotor running.
The instrument is based on a single-chip microcontroller, which ensures good accuracy, stability and easy operation of the instrument.
-
6 digit programmable projection
-
input: BCD/transformer tapping lead
-
digital filters, math. functions
-
size of DIN 96 x 48 mm
-
power supply 9…50 V AC/DC nebo 80…250 V AC/DC
Options
-
excitation
-
comparators
-
data output
-
analog output
Input
BCD display
Range
5…24 VDC
10…60 VDC
10…60 VDC
Measurement mode
Parallel BCD - 24 bit
Binary - 20 bit
Serial BCD - 4 data/6 Strobe
Serial BCD - 8 data/3 Strobe
Serial BCD - 13 data/2 Strobe
Serial BCD - 4 data/1 Strobe/3 Segments
Binary - 20 bit
Serial BCD - 4 data/6 Strobe
Serial BCD - 8 data/3 Strobe
Serial BCD - 13 data/2 Strobe
Serial BCD - 4 data/1 Strobe/3 Segments
Address
up to 8 projections
BCD - transformer tapping display
Range
5…24 VDC
10…60 VDC
90…130 VDC
190…250 VDC
10…60 VDC
90…130 VDC
190…250 VDC
Number of tapping leads
24 + 1 signalization
(on request 27)
(on request 27)
Input resistence
5,5 kOhm/V
Output
relay BIN/BCD
5 relays (250 VAC/50 VDC, 3 A)
Relay mode
5 relays (250 VAC/50 VDC, 3 A)
Relay mode
Projection
Display range
-99999…999999, single-coloured 14-segment LED
Display height
14 mm
Display colour
red, green
Signalizing LED
| 1, 2, 3, 4 | Limits L1, L2, L3, L4 (red) |
| M | Min./Max. value (green) |
Description
the last two digits of the display can be used to display measured variables (only 14 mm display)
Displayed values
| Kan A | Value from channel A |
| Fil. A | Value from channel A after digital filter adjustment |
| Mat. Fn. | Value of mathematical function |
| Max. | Maximum value |
| Min. | Minimum value |
Settings
Control
The device is controlled and set by five buttons on the front panel
Menu
| PROFI | Full device settings with password access |
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Digital filters
| floating mean | from 2…30 measurements |
| exponential mean | from 2…100 measurements |
| rounding | setting projection step for display |
Functions
| Min/max value | registration of min./max. value achieved during measurement |
Math. functions
polynom, 1/x, logarithm, exponential, power, root, sin x
Watch-dog
reset after 1,2 s
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
| Hysteresis | switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay |
| Dose | period, its multiples and time (0 ... 99.9 s), during which the output is active |
Output
1x relay, switch-over contact (250 VAC/30 VDC, 3 A)
2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
3x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
3x relay, switch on contact (250 VAC/30 VDC, 3A)
Analogue outputs
Type
Isolated, programmable with resolution of max.10,000 steps, type and range are menu selectable
Temperature coefficient
50 ppm/°C
Nonlinearity
±0,2 % of range
Rate
response to value change < 40 ms
Ranges
0...2 V, 0...5 V, 0...10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V
Data outputs
Protocol
ASCII, MESSBUS
Data format
8 bits + no parity + 1 stop bit (ASCII)
7 bits + even parity + 1 stop bit (Messbus)
7 bits + even parity + 1 stop bit (Messbus)
Rate
1 200…38 400 Baud
RS 232
isolated
RS 485
isolated, addressing max. 31 instruments
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
9…50 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 6,5 W/6,0 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Mechanical properties
Dimensions
96 x 48 x 154 mm (w x h x d)
Panel cutout
90,5 x 45 mm (w x h)
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Operating conditions
Connection
connector terminal board, cable section < 2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
| power supply | 670 V (ZI), 300 V (Di)* |
| input, output, PN | 300 V (ZI), 150 V (Di)* |
EMC
EN 61326-1
Datasheets
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Datasheet OM621BCD
Katalogový list OM621BCD
|
PDF
|
2026.2 |
|
Download |
|
Datasheet OM621BCD
Katalogový list OM621BCD
|
PDF
|
2023.1 |
|
Download |
|
Datasheet OM621BCD
Datasheet OM621BCD
Datasheet OM621BCD
Katalogový list OM621BCD
|
PDF
|
2020.1 |
|
Download |
User manuals
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
| Operating instructions OM621BCD |
PDF
|
2017.5 | en | Download |
| Návod OM621BCD |
PDF
|
2016.4.1 | cs | Download |
| Návod OM621BCD |
PDF
|
2003.4 | cs | Download |
Certificates
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Certificate EU_Declaration_OM621
Certifikát EU_Prohlaseni_OM621
|
PDF
|
2022 |
|
Download |
|
Certificate Declaration_17050_OM621
Certifikát Prohlaseni_17050_OM621
|
PDF
|
2022 |
|
Download |
Software
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
| sw_OM621BCD 2003.v041_cs.pdf |
PDF
|