Input
RS
Protocol
ASCII
ASCII - Master
ASCII - Slave
ASCII - Universal
MODBUS RTU
Format
8 bits + no parity + 1 stop bit
Line termination
short circuit connector socket
Projection
Display range
-999…9999, single-coloured 7-segment LED
Display colour
red, green
Decimal point
menu adjustable - fixed or floating
Display brightness
menu adjustable, automatically
Settings
Control
The device is controlled and set by four buttons located under the front panel
Menu
|
LIGHT
|
contains only items necessary for basic device settings with password access
|
|
PROFI
|
Full device settings with password access
|
|
USER
|
User menu of any item, selected from LIGHT/PROFI. Access without password.
|
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Digital filters
|
exponential mean
|
from 2…100 measurements
|
|
rounding
|
setting projection step for display
|
Watch-dog
reset after 500 ms
Calibration
at 25°C and 40 % r.h.
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current draw
< 1,0 W/1,1 VA
Operating conditions
Connection
connector terminal board, cable section < 1,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP42 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC within 1 min. between pow. supply and input
Insulation resistance
for polution degree II, measuring cat. III.
Mechanical properties
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Dimensions
48 x 24 x 72 mm (w x h x d)
Panel cutout
43,5 x 21,5 mm (w x h)
Images
Dimensions and installation
{"ds01-6949-2015.1-en":"11871","ds01-6949-2015.1-fr":"11872","ds01-6949-2015.1-ru":"11873","ds01-6949-2015.1-cs":"11883","ds01-6949-2014.2-en":"11868","ds01-6949-2014.2-fr":"11869","ds01-6949-2014.2-ru":"11870","ds01-6949-2014.2-cs":"11882","ds01-6949-2014.1-en":"11865","ds01-6949-2014.1-fr":"11866","ds01-6949-2014.1-ru":"11867","ds01-6949-2014.1-cs":"11881","ds01-6949-2013.2-en":"11862","ds01-6949-2013.2-fr":"11863","ds01-6949-2013.2-ru":"11864","ds01-6949-2013.2-cs":"11880","ds01-6949-2013.1-ru":"11861","ds01-6949-2012.2-en":"11858","ds01-6949-2012.2-fr":"11859","ds01-6949-2012.2-ru":"11860","ds01-6949-2012.2-cs":"11879","ds01-6949-2023.1-en":"10211","ds01-6949-2023.1-cs":"10212","ds01-6949-2020.1-en":"11855","ds01-6949-2020.1-fr":"11856","ds01-6949-2020.1-ru":"11857","ds01-6949-2020.1-cs":"11877","ds01-6949-2019.1-en":"11852","ds01-6949-2019.1-fr":"11853","ds01-6949-2019.1-ru":"11854","ds01-6949-2019.1-cs":"11876","ds01-6949-2017.1-en":"11850","ds01-6949-2017.1-ru":"11851","ds01-6949-2017.1-cs":"11875","ds01-6949-2012.1-cs":"11878","ds01-6949-2016.1-cs":"11874","man03-6950-2015.1.0-en":"5808","man03-6950-2015.1.0-cs":"5807","man04-6950-2014.1.0-en":"5815","man05-6950-2013.1.0-cs":"5821","an05-6951-2020.01-en":"2474","an05-6951-2020.01-cs":"3492","crt02-6952-2022-en":"13283","crt02-6952-2022-cs":"13284","crt03-6952-2022-en":"13089","crt03-6952-2022-cs":"13090","crt04-6952-2021-en":"5809","crt04-6952-2021-cs":"5810","fw01-6953-2018-xx":"5798"}