OMX 390LVDT
FAST ISOLATED TRANSMITTER • LVDT > U/I
The OMX 390 model series are very fast DIN rail mountable digital transmitters with a Teach-in function.
Type OMX 390LVDT is a transmitter for LVDT sensors. Setting of both the input and output ranges can be done conveniently by a DIP switch located on the side of the housing or from a PC via the OM Link SW. This device is based on a 32-bit processor, dual 24-bit ∆Σ ADC with PGA, demodulato, wake-up signal generator and 16-bit DAC, which guarantees high accuracy and excellent stability.
-
Power supply of LVDT sensor 1 / 3 / 5 Vac
-
3- / 4- / 5- / 6-wire connection
-
Teach-in, Digital filters, Tare, Linearization
-
Quick configuration by DIP switch
-
PC configurable via USB port
-
Galvanic separation 2.5 kVAC
-
Power supply 10…30 VDC/24 VAC
Input
LVDT
Range
1/3/5 VAC with frequency of 2.5/5/10 kHz
Wiring
3, 4, 5 nebo 6drátové
Settings
Control
Přístroj se ovládá a nastavuje dvěna tlačítky na předním panelu a DIP přepínačem na boku krabičky
Optional functions
| TARE | Activating function Tare |
| NUL. TA. | Tare reset |
| Teach-in | setting the analog input range |
OM Link
Company communication interface for operation, setting and update of device firmware (microUSB)
OM Link program is also designed for visualization and filing of meas. values from more instruments
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
15 ppm/°C
Accuracy
±0,1 % of range
Rate
1…100 measur./s
Overload capacity
2x; 10x (t < 30 ms)
Linearization
lineární interpolací v 100 bodech (pouze přes OM Link)
Digital filters
| arithmetic mean | from 2…100 measurements |
| floating mean | from 2…30 measurements |
| exponential mean | from 2…100 measurements |
| rounding | setting projection step for display |
Functions
| Tare | designed to reset display on non-zero input signal |
| Offset | kompenzace rozdílu mezi měřenou a skutečnou/požadovanou hodnotou |
| Min/max value | registration of min./max. value achieved during measurement |
| Teach-in | semiautomatic regime of input calibration |
| Simulace | simulace vstupního signálu/funkce přístroje |
| Odložený start | čas kdy se neprovádí měření po připojení přístroje k napájení |
Math. functions
polynom, invertní polynom, 1/x, logarithm, exponential, power, root
Watch-dog
reset after 500 ms
Calibration
at 25°C and 40 % r.h.
Analogue outputs
Number of outputs
1 output
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Accuray
±0,02 % full scale
±0,03 % full scale (0…5 V)
±0,05 % full scale (0…2 V / 0…5 mA)
±0,03 % full scale (0…5 V)
±0,05 % full scale (0…2 V / 0…5 mA)
Rate
response to value change < 160 µs
Ranges
0…2 / 5 / 10 V, ±10 V, resistive load > 1 k?
0…5 / 20 mA / 4…20 mA, comp. < 600 Ohm / V
0…5 / 20 mA / 4…20 mA, comp. < 600 Ohm / V
Error state
error message indication (<3.0 mA)
Data outputs
Number of outputs
1 outputs
Type
RS 485, isolated
10/100BaseT, Modbus TCP/IP (Slave)
10/100BaseT, Modbus TCP/IP (Slave)
Protocol
MODBUS - RTU, MODBUS - TCP/IP
Data format
| Format | 8bit + parity + stop bit |
| Parity | none / even / odd |
| Stop bit | 1 / 1.5 / 2 |
Rate
600…230 400 Baud
10 Mbit/s, 100 Mbit/s
10 Mbit/s, 100 Mbit/s
RS 485
isolated, addressing max. 31 instruments
Address
| MODBUS | < 246 instruments |
Line termination
by internal resistor 120 Ohm
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current draw
< 3,5 W/3,9 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Mechanical properties
Dimensions
25 x 79 x 90 mm (w x h x d)
Material
PA 66, non-inflammable UL 94 V-0 (black)
Installation
DIN rail, width 35 mm
Operating conditions
Connection
connector terminal board, cable section < 1,5 mm2
Stabilization period
within 5 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Operating humidity
< 95 % r.v., nekondenzující
Protection class
IP20
El. safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC within 1 min. between pow. supply and input
2,5 kVAC po 1 min. mezi vstupem a výstupem
2,5 kVAC po 1 min. mezi vstupem a výstupem
Insulation resistance
for polution degree II, measuring cat. III.
| napájení přístroje | 300 V (ZI), 255 V (DI) |
| input, output | 300 V (ZI)* |
EMC
EN 61326-1
RoHS
IEC 63000 : 2018
Seismic capacity
IEC/IEEE 60980-344 ed. 1.0:2020, par 6,9
Mechanical durability
EN 60068-2-6 ed. 2:2008
Datasheets
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Datasheet OMX390LVDT
Katalogový list OMX390LVDT
|
PDF
|
2026.2 |
|
Download |
User manuals
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Operating instructions OMX390LVDT_AO
Návod OMX390LVDT_AO
|
PDF
|
2024.1.02 |
|
Download |
|
Operating instructions OMX390LVDT_RS
Návod OMX390LVDT_RS
|
PDF
|
2024.1.02 |
|
Download |
|
Operating instructions OMX390LVDT_ETH
Návod OMX390LVDT_ETH
|
PDF
|
2024.1.02 |
|
Download |
Application notes
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Application note External inputs
Aplikační list Externí vstupy
|
PDF
|
2024.1 |
|
Download |
Certificates
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Certificate EU_Declaration_OMX390
Certifikát EU_Prohlášení_OMX390
|
PDF
|
2024 |
|
Download |
|
Certificate Declaration_17050_OMX390
Certifikát Prohlaseni_17050_OMX390
|
PDF
|
2024 |
|
Download |
|
Certificate Seismic_test_OMX390
Certifikát Seizmicka_zkouzka_OMX390
|
PDF
|
2024 |
|
Download |
CAD
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
| OMX380iT |
STEP
|
2023 | xx | Download |
| OMX380iT_ETH |
STEP
|
2023 | xx | Download |