OM 602AV
6 digit PROGRAMMABLE ANALOG OUTPUT
Type OM 602AV is a programmable analog output. The instrument is based on a single-chip microcontroller with a precise D/A converter, which ensures good accuracy, stability and easy operation of the instrument.
-
6 digit programmable projection
-
output: 0…5 mA; 0…20 mA; 4…20 mA; 0…2 V; 0…5 V; 0…10 V; ±10 V
-
sinus/saw/triangle/random value
-
size of DIN 96 x 48 mm
-
power supply10…30 V AC/DC or 80…250 V AC/DC
Options
-
excitation
-
comparators
-
data output
-
tree-color display - 20 mm
Input
AV
Type
isolated, programmable with a 16bit D/A transducer
output type and range are selectable in menu
output type and range are selectable in menu
Range
0…2 V
0…5 V
0…10 V
±10 V
0…5 V
0…10 V
±10 V
0…5 mA
compensation < 1 000 Ohm/24 V
0…20 mA
compensation < 1 000 Ohm/24 V
4…20 mA
compensation < 1 000 Ohm/24 V
Nonlinearity
0,1 % of range
Temperature coefficient
15 ppm/°C
Rate
response to value change < 1 ms
Functions
device sources signal within the set range and frequency
In addition, you can set min. and max. time for signal changes and the number of generated pulses
TROJUH. :. triangle output signal
In addition, you can set min. and max. time for signal changes and the number of generated pulses
| RUCNE | manual setting of output value |
| SINUS | sinus output signal |
| PILA | saw output signal |
| OBDEL. | rectangular output signal |
| NAHOD. | random generated signal |
External inputs
Number
3 inputs, on contact
Functions
| OFF | No function |
| HOLD | Stopping measurement (option: Display - Analog output - Limits) |
| BLOK.K. | Blocking front panel keys |
| B.HESL. | Blocking access to the LIGHT/PROFI menu |
| NUL. M.M. | Resetting Min/Max. value |
| K1 NAH. | Gross step - Up |
| K1 DOL. | Gross step - Down |
| K2 NAH. | Fine step - Up |
| K2 DOL. | Fine step - Down |
| MIN. H. | Minimum range |
| MAX. H. | Maximum range |
| ZVYSUJ | Increases output every 10 ms one "Step" |
| SNIZUJ | Decreases output every 10 ms one "Step" |
| START | Starting preset cycle |
| STOP | Stopping preset cycle |
| ST.-ST. | Start/Stop of the preset cycle |
Projection
Display range
-99999…999999, single-coloured 14-segment LED
-999…9999, 3-coloured 7-segment LED
-999…9999, 3-coloured 7-segment LED
Display height
14 mm, 20 mm
Display colour
red, green, red/green/orange
Signalizing LED
| 1, 2, 3, 4 | Limits L1, L2, L3, L4 (red) |
Description
the last two digits of the display can be used to display measured variables (only 14 mm display)
Decimal point
menu adjustable - fixed or floating
Display brightness
menu adjustable
Displayed values
| Kan A | Value from channel A |
| Fil. A | Value from channel A after digital filter adjustment |
| Mat. Fn. | Value of mathematical function |
Settings
Control
The device is controlled and set by five buttons on the front panel
Selected functions can also be controlled via external inputs
Selected functions can also be controlled via external inputs
Menu
| LIGHT | contains only items necessary for basic device settings with password access |
| PROFI | Full device settings with password access |
| USER | User menu of any item, selected from LIGHT/PROFI. Access without password. |
Optional functions
Buttons "Left", "Up", "Down", "Enter" can be assigned additional optional features
| ZAKAZ | button has no function |
| MENU | Direct access to the selected menu item |
| RUCNE | Manual setting |
| START | Starting set cycle |
| STOP | Stopping set cycle |
| ST.-ST. | Start/Stopof the set cycle |
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Math. functions
polynom, 1/x, logarithm, exponential, power, root, sin x
Watch-dog
reset after 400 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
| Hysteresis | switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay |
| From-To | output interval ON and OFF |
| Dose | period, its multiples and time (0 ... 99.9 s), during which the output is active |
Output
1x relay, switch-over contact (250 VAC/30 VDC, 3 A)
2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
2x bistable relay (250 VAC/30 VDC, 3A)
3x relay, 2x switch on + 1x switch-over contact (250 VAC/30 VDC, 3A)
4x relay, 2x switch on + 2x switch-over contact (250 VAC/30 VDC, 3A)
2x open collector (30 VDC/100 mA)
4x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA) + 2x relay, CO contact (250 VAC/30 VDC, 3 A)
2x SSR (250 VAC/1 A)
2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
2x bistable relay (250 VAC/30 VDC, 3A)
3x relay, 2x switch on + 1x switch-over contact (250 VAC/30 VDC, 3A)
4x relay, 2x switch on + 2x switch-over contact (250 VAC/30 VDC, 3A)
2x open collector (30 VDC/100 mA)
4x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA) + 2x relay, CO contact (250 VAC/30 VDC, 3 A)
2x SSR (250 VAC/1 A)
Data outputs
Protocol
ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
Data format
8 bits + no parity + 1 stop bit (ASCII)
7 bits + even parity + 1 stop bit (Messbus)
7 bits + even parity + 1 stop bit (Messbus)
Rate
600…230 400 Baud
0,0096…12 MBaud (PROFIBUS)
0,0096…12 MBaud (PROFIBUS)
RS 232
isolated
RS 485
isolated, addressing max. 31 instruments
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 9,4 W/9,2 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Mechanical properties
Dimensions
96 x 48 x 120 mm (w x h x d)
Panel cutout
90,5 x 45 mm (w x h)
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Operating conditions
Connection
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
| power supply | 670 V (ZI), 300 V (Di)* |
| input, output, PN | 300 V (ZI), 150 V (Di)* |
EMC
EN 61326-1
Seismic capacity
IEC 980: 1993, par.6
SW validation
Compliance with IEC 62138, 61226, class B, C
Datasheets
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Datasheet OM602AV
Katalogový list OM602AV
|
PDF
|
2023.1 |
|
Download |
|
Datasheet OM602AV
Datasheet OM602AV
Datasheet OM602AV
Katalogový list OM602AV
|
PDF
|
2020.1 |
|
Download |
User manuals
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Operating instructions OMProfi
Návod OMProfi
|
PDF
|
2020.3 |
|
Download |
|
Operating instructions OM602AV
Návod OM602AV
|
PDF
|
2014.3.0 |
|
Download |
|
Operating instructions OMProfibus
Návod OMProfibus
|
PDF
|
2014.2.1 |
|
Download |
| Návod OMProfibus |
PDF
|
2014.2.0 | cs | Download |
|
Operating instructions OMProfibus
Návod OMProfibus
|
PDF
|
2010.1.2 |
|
Download |
| Návod OMProfibus |
PDF
|
2007.1.0 | cs | Download |
| Operating instructions OMProfibus |
PDF
|
2010.1.1 | en | Download |
|
Operating instructions OM602AV
Návod OM602AV
|
PDF
|
2006.2.0 |
|
Download |
Application notes
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Application note Handling RealTime memory
Aplikační list Obsluha pameti RealTima
|
PDF
|
2006.01 |
|
Download |
|
Application note Firmware upload
Aplikační list Upload firmware
|
PDF
|
2006.02 |
|
Download |
| Application note Upload firmware |
PDF
|
2014.02 | ru | Download |
|
Application note Modbus commands OM 602AV
Aplikační list Modbus prikazy OM 602AV
|
XLS
|
2017 |
|
Download |
|
Application note Modbus commands OM 602AV-20
Aplikační list Modbus prikazy OM 602AV-20
|
XLS
|
2015 |
|
Download |
| Application note Protocol MODBUS description |
PDF
|
2006.01 | en | Download |
| Aplikační list protokol MODBUS popis |
PDF
|
2021.01 | cs | Download |
Certificates
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Certificate EU_Declaration_OM602
Certifikát EU_Prohlaseni_OM602
|
PDF
|
2022 |
|
Download |
|
Certificate Declaration_17050_OM602
Certifikát Prohlaseni_17050_OM602
|
PDF
|
2022 |
|
Download |
|
Certificate Seismic_test_OM602AV
Certifikát Seizmicka_zkouzka_OM602AV
|
PDF
|
2007 |
|
Download |
Firmware
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
| OM 602AV 78-502 |
HEX
|
2017 | xx | Download |
Software
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
| GSD OM-Profibus |
ZIP
|
2020 | xx | Download |
| GSDML OM-Profinet |
ZIP
|
2020.2.33 | xx | Download |
| GSDML OM-Profinet |
ZIP
|
2024.2.33 | xx | Download |
CAD
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
| OM Krabicka |
DWG
|
2014 | xx | Download |