OMB 502UNI
UNIVERSAL BARGRAPH - 2x 50 LED
The OMB 200/300/500UNI model series are simple bargraphs designed for maximum efficiency and user comfort while maintaining their low cost.
The OMB 502UNI type is a multifunction two-channel instrument with the option of configuration for 5 different types of inputs easily configurable in the instrument menu.
The instrument is based on a single-chip microcontroller with A/D converter, which secures good accuracy, stability and easy operation of the instrument.
By selecting the mode of insertion of the front plexiglass (reverse/face) you may choose the required printing of scale for vertical or horizontal design of the instrument.
-
three - color bargraph - 2x 50 LED
-
two - channel design
-
multifunction input (PM, OHM, RTD, DU)
-
digital filters, linearization
-
size of DIN 144 x 48 mm
-
power supply 10…30 V AC/DC or 80…250 V AC/DC
Options
-
comparators
Input
PM
Range
menu selectable
2 inputs
2 inputs
0…20 mA
< 1,2 V
Input 1
4…20 mA
< 1,2 V
Input 1
0…2 V
182 kOhm
Input 2
0…5 V
182 kOhm
Input 2
0…10 V
182 kOhm
Input 2
OHM
Range
menu selectable
2 inputs
0…100 kOhm
2 inputs
0…100 kOhm
Connection
2-wire
RTD
Type
menu selectable
2 inputs
2 inputs
EU > 1 000 Ohm s 3 850 ppm/°C
-50°…450°C
Ni
Type
menu selectable
2 inputs
2 inputs
Connection
2-wire
External inputs
Number
1 input, on contact
Functions
| OFF | No function |
| HOLD | Stopping measurement (option: Display - Analog output - Limits) |
| LOCK | Blocking front panel keys |
Projection
Display range
2x 50 LED
Display colour
red/green/orange
Signalizing LED
| 1, 2 | Limits L1, L2 (red) |
Display brightness
menu adjustable
Settings
Control
The device is controlled and set by five buttons located under the front panel
Selected functions can also be controlled via external inputs
Selected functions can also be controlled via external inputs
Menu
| LIGHT | contains only items necessary for basic device settings with password access |
| PROFI | Full device settings with password access (only via OM Link) |
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±1 % of range + 1 digit
Rate
0,5/5/50/Max measur./s
Overload capacity
2x; 10x (t < 30 ms)
Wire compensation (RTD, OHM)
< 30 Ohm
Linearization
linear interpolation in 25 points (only via OM Link)
Digital filters
| exponential mean | from 2…100 measurements |
| rounding | setting projection step for display |
Watch-dog
reset after 25 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 50 ms
Mode
| Hysteresis | switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay |
Output
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
1x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
1x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA)
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current draw
< 5,0 W/5,4 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Mechanical properties
Dimensions
144 x 48 x 75 mm (w x h x d)
Panel cutout
138 x 43,5 mm (w x h)
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Operating conditions
Connection
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP40 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
| power supply | 670 V (ZI), 300 V (Di)* |
| input, output, PN | 300 V (ZI), 150 V (Di)* |
EMC
EN 61326-1
Datasheets
User manuals
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Operating instructions OMB50xUNI
Návod OMB50xUNI
Operating instructions OMB50xUNI
|
PDF
|
2013.3.0 |
|
Download |
| Operating instructions OMB50xUNI |
PDF
|
2011.1.1 | en | Download |
| Návod OMB50xUNI |
PDF
|
2010.1.2 | cs | Download |
| Návod OMB50xUNI |
PDF
|
2010.1.1 | cs | Download |
Certificates
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
Certificate EU_Declaration_OMB2_3_500
Certifikát EU_Prohlaseni_OMB2_3_500
|
PDF
|
2022 |
|
Download |
|
Certificate Declaration_17050_OMB2_3_500
Certifikát Prohlaseni_17050_OMB2_3_500
|
PDF
|
2022 |
|
Download |
|
Certificate Seismic_test_OMB50x
Certifikát Seizmicka_zkouzka_OMB50x
|
PDF
|
2021 |
|
Download |