ISOLATED TRANSMITTER • Number/Frequency > U/I

The OMX 333 model series are simple DIN rail mountable programmable transmitters.
Type OMX 333UQC is a universal transmitter - counter/frequency meter/timer/clock adjustable in the instrument´s menu.
The instrument is based on a single-chip microcontroller, which ensures good accuracy, stability and easy operation of the instrument.

  • input: 0,1 Hz…50 kHz; UP/DW; IRC
  • counter/frequency meter/timer/clock
  • output: 0…5/20 mA/4…20 mA
    0…2/5/10 V/±10 V
  • tare, preset, sum, linearization
  • digital filters, input filters
  • galvanic isolation :  2,5 kVAC
  • width 25 mm
  • DIN rail mounting
  • power supply 10…30 VDC/24 VAC

 

Input
UQC
Input
menu selectable
0...30/300 V, comparation levels are adjustable in the menu or automatically
Input frequency
0,1 Hz…50 kHz (Mode SINGLE)
0,1 Hz…20 kHz (Mode UP/DW)
0,1 Hz…20 kHz (UP-DW)
0,1 Hz…20 kHz (Mode QUADR. - frequency)
0,1 Hz…10 kHz (Mode QUADR. - counter)
(for duty cycle 50%)
Measurement mode
SINGLE Counter/Frequency
QUADR Counter/Frequency for IRC sensor
UP/DW Counter/Frequency
UP - DW Counter/Frequency
TIME Stopwatch
RTC Clock
Time base
0,5/1/2/5/10 s
Calibration coefficient
0,00001…999999
Preset
0…999999
Input filter
out
5/40/100/1 000 Hz
Functions
Preset initial non-zero value, which is always read after resetting the instrument
Current value single setting of the initial value
Summation registration of numbers during shift operation
External inputs
Number
1 input, on contact
Functions
OFF No function
HOLD Stopping measurement (option: Display - Analog output - Limits)
LOCK Blocking front panel keys
TARA Tare activation
CL.SUM. Resetting sum
CLR. ST. Input clears (presets) stop-watch/counter, Stop-watch also stops
Projection
Signalizing LED
L1, L2 Limits L1, L2 (red)
Lo, Hi Signalization, settings and errors (red/green)
Settings
Control
The instrument is controlled and set by two buttons and a DIP switch on the front panel
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±0,1 % of range
Rate
0,5…80 measur./s
Overload capacity
2x; 10x (t < 30 ms)
Linearization
linear interpolation in 25 points (only via OM Link)
Digital filters
exponential mean from 2…100 measurements
rounding setting projection step for display
input filter transmits input signal range 5…1 000 Hz
1/Fr. filter for frequency conversion to time
Functions
Tare designed to reset display on non-zero input signal
Preset initial non-zero value, which is read after each counter reset
Summation number registration upon shift operation
Watch-dog
reset after 500 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 50 ms
Mode
Hysteresis switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
C-Pulse auto counter reset on the preset value
Once switching ON limit, however it opens only after a counter reset
On Run output is active while stopwatch is running
Output
1x relay, switch-over contact (250 VAC/30 VDC, 3 A)
2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
1x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA)
Data outputs
Protocol
ASCII
Data format
8 bits + no parity + 1 stop bit (ASCII)
Rate
600…230 400 Baud
RS 485
isolated, addressing max. 31 instruments
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Nonlinearity
±0,1 % of range
Rate
response to value change < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruption
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 2 W/2 VA
Operating conditions
Connection
connector terminal board, cable section < 1,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP20
El. safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC within 1 min. between pow. supply, input and output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply 550 V (ZI), 255 V (Di)*
EMC
EN 61326-1
Mechanical properties
Material
PA 66, non-inflammable UL 94 V-I (blue)
Dimensions
25 x 79 x 110 mm (w x h x d)
Installation
DIN rail, width 35 mm
Images
Connection
Dimensions and installation
To assemble the order, first select the desired instrument configuration.
OMX 333UQC-???-??
Power supply
Any
?
Any
?
10...30 VDC/24 VAC, non isolated
0
10...30 VDC/24 VAC, isolated
1
Comparators
Any
?
Any
?
No
0
1x relay
1
2x relay
2
1x open collector
3
2x open collector
4
Output
Any
?
Any
?
No
0
Analogue
1
RS 485
2
Extension
Any
??
Any
??
Standard
00
Selected combination is invalid
Alternatives in stock
OMX 333UQC-101-00In stock < 5 pcs

Micro USB 2.0 cable, A-B with a length of 2 m, for connecting devices to a PC.
Double shielded 2x AWG28, supports up to 480 Mbps.

ISOLATED TRANSDUCER • USB < > OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.