Skip to main content

OM 402PID

OM 402PID

4 DIGIT VERSATILE PID REGULATOR

The OM 402PID is a versatile 4 digit panel PID regulator designed for maximum flexibility and user comfort while maintaining its fair price. Type OM 402PID is a multifunction instrument with the option of configuration for 8 various input options, easily configurable in the instrument menu. In its basic configuration the OM 402PID has two regulatory relays and two relay alarm outputs. Desired value can either be constant or defined by one of 14 programmes. The instrument is based on a single-chip microcontroller with a multichannel 24-bit sigma-delta converter, which ensure good accuracy, stability and easy operation of the instrument.

 

  • 4 digit programmable projection
  • multifunction input (DC, PM, RTD, T/C, DU)
  • P/PI/PID regulation
  • 4 contact outputs
  • RTC with measured data record
  • digital filters, tare, linearization
  • size of DIN 96 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  •  data output

  • analog output

  • input for Desired value

 

Input
DC
Range
menu selectable
±60 mV
> 100 MOhm
Input U
±150 mV
> 100 MOhm
Input U
±300 mV
> 100 MOhm
Input U
±1200 mV
> 100 MOhm
Input U
PM
Range
menu selectable
0…20 mA
< 400 mV
Input I
4…20 mA
< 400 mV
Input I
±2 V
1 MOhm
Input U
±5 V
1 MOhm
Input U
±10 V
1 MOhm
Input U
±40 V
1 MOhm
Input U
Requested value
optional extension - according to order
range and setting is the same as for "PM" selection
connection to inputs "Requested value"
OHM
Range
selectable in the menu with automatic change of the range
0…100 Ohm
0…1 kOhm
0…10 kOhm
0…100 kOhm
Connection
2, 3 or 4-wire
RTD
Type
menu selectable
EU > 100/500/1 000 Ohm s 3 850 ppm/°C
-50°…450°C
RU > 50 Ohm s 3 910 ppm/°C
-200°…1 100°C
RU > 100 Ohm s 3 910 ppm/°C
-200°…450°C
US > 100 Ohm s 3 920 ppm/°C
-50°…450°C
Connection
2, 3 or 4-wire
Ni
Type
menu selectable
Ni 1 000/10 000 s 5 000 ppm/°C
-50°…250°C
Ni 1 000/10 000 s 6 180 ppm/°C
-50°…250°C
Cu
Type
menu selectable
Cu 50/100 with 4 260 ppm/°C
-50°…200°C
Cu 50/100 with 4 280 ppm/°C
-200°…200°C
T/C
Type
selecmenu selectable
J (Fe-CuNi)
-200°…900°C
K (NiCr-Ni)
-200°…1 300°C
T (Cu-CuNi)
-200°…400°C
E (NiCr-CuNi)
-200°…690°C
B (PtRh30-PtRh6)
300°…1 820°C
S (PtRh10-Pt)
-50°…1 760°C
R (Pt13Rh-Pt)
-50°…1 740°C
N (Omegalloy)
-200°…1 300°C
L (Fe-CuNi)
-200°…900°C
DU
Potentiometer power supply
2 VDC/6 mA, potentiometer resistance > 500 Ohm
External inputs
Number
3 inputs, on contact
Functions
OFF No function
HOLD Stopping measurement (option: Display - Analog output - Limits)
BLOK.K. Blocking front panel keys
B.HESL. Blocking access to the LIGHT/PROFI menu
TARA Tare activation
NUL. TA. Resetting tare
NUL. M.M. Resetting Min/Max. value
ULOZ Data record activation (extention of RTC/FAST)
NUL. PA. Resetting memory (extention of RTC/FAST)
STOP R. Regulation stop
STAR. P Starting regulation on fixed setpoint
STAR. A Starting regulation on fixed input setpoint „Requested value"
Projection
Secondary display
2x -999…9999, green LED, height 9 mm
upper display shows the number of programme/step
lower display shows the requested value
Display height
9,1 mm, 14 mm
Display colour
red, green
Signalizing LED
1, 2, 3, 4 Limits L1, L2, L3, L4 (red)
+, -, 3, 4 Regulation (yellow)
T, t Tare real/requested (green)
Decimal point
menu adjustable - fixed or floating
Display brightness
menu adjustable
Displayed values
Kan A Value from channel A
Fil. A Value from channel A after digital filter adjustment
Max. Maximum value
Min. Minimum value
Settings
Control
The device is controlled and set by five buttons on the front panel
Selected functions can also be controlled via external inputs
Menu
LIGHT contains only items necessary for basic device settings with password access
PROFI Full device settings with password access
USER User menu of any item, selected from LIGHT/PROFI. Access without password.
Optional functions
Buttons "Left", "Up", "Down", "Enter" can be assigned additional optional features
ZAKAZ button has no function
NUL. M.M. Resetting Min/Max vaslues
NUL. TA. Tare reset
MENU Direct access to the selected menu item
DOC. H. Temporary projection of selected values
TARA Activating function Tare
PROG. x Program start (1 - 14)
STOP R. Stopping regulation
STAR. P Starting regulation on fixed value
STAR. A Starting regulation on fixed input value "Requested value"
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±0,1 % of range + 1 digit
±0,15 % of range + 1 digit (RTD, T/C)
(for projection 9999 and 5 measur./s)
Accuracy of cold junction measurement
±1,5°C
Rate
0,1…40 measur./s
Overload capacity
2x; 10x (t < 30 ms)
Resolution (RTD, T/C)
1°C, 0,1°C, 0,01°C
Wire compensation (RTD, OHM)
< 30 Ohm
Cold junction compensation
adjustable -20°…99°C, automatic
Linearization
linear interpolation in 50 points (only via OM Link)
Digital filters
arithmetic mean from 2…100 measurements
floating mean from 2…30 measurements
exponential mean from 2…100 measurements
rounding setting projection step for display
Functions
Tare designed to reset display on non-zero input signal
Fixed tare preset fixed tare
Min/max value registration of min./max. value achieved during measurement
Peak value display shows only max. or min. values
Regulation
Type Parallel PID, PI or proportional
Constants Proportional, integral and derivative
Requested value fix, from analogue input, from programme
Number of programmes 14
Number of steps 64
Starting time - once/weekly; by external input, by keys
Data record
Measured data recording into the memory
RTC period - 1 s…1 day, time-date-display value, < 266k data, 15 ppm/°C
Not available in combination with with the data output MODBUS
Watch-dog
reset after 400 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
Hysteresis switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay
From-To output interval ON and OFF
Bistable L3 switches at negative deviation (INCREASE), L4 switches at positive deviation (DECREASE)
PWM L3 switches at negative deviation (INCREASE), L4 switches at positive deviation (DECREASE)
Program relay is active after program completion; if the set time is "0", then permanently, otherwise "CAS L2"
Ready
Output
2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
2x SSR (250 VAC/1 A)
Data outputs
Protocol
ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
Data format
8 bits + no parity + 1 stop bit (ASCII)
7 bits + even parity + 1 stop bit (Messbus)
Rate
600…230 400 Baud
0,0096…12 MBaud (PROFIBUS)
RS 232
isolated
RS 485
isolated, addressing max. 31 instruments
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Nonlinearity
±0,1 % of range
Rate
response to value change < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V, 1 000 Ohm/24 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruption
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current draw
< 9,4 W/9,2 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Operating conditions
Connection
connector terminal board, cable section < 1,5/2,5 mm2
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64 (front panel only)
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
power supply 670 V (ZI), 300 V (Di)*
input, output, PN 300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Mechanical properties
Material
Noryl GFN2 SE1, non-inflammable UL 94 V-I
Dimensions
96 x 48 x 120 mm (w x h x d)
Panel cutout
90,5 x 45 mm (w x h)
Images
Connection
Dimensions and installation
To assemble the order, first select the desired instrument configuration.
OM 402PID-??????
Power supply
Any
?
Any
?
10...30 V AC/DC
0
80...250 V AC/DC
1
Extension
Any
?
Any
?
No
0
Yes
A
Comparators
Any
?
Any
?
2x normally open relay + 2x relay (switch-over)
0
2x normally open relay + 2x SSR
1
On request
Z
Analogue output
Any
?
Any
?
No
0
Yes (500 Ohm/12 V)
1
Yes (1 kOhm/24 V)
2
Data output
Any
?
Any
?
No
0
RS 232
1
RS 485
2
MODBUS RTU
3
PROFIBUS
4
Excitation
Any
?
Any
?
No
0
Yes
1
Selected combination is invalid
For the selected combination there are no devices in stock

Datasheets

File name File type Version Language Download
Datasheet OM402PID
Datasheet OM402
Datasheet OM402
Datasheet OM402
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402
Katalogový list OM402PID
PDF
2015.1
Download
Datasheet OM402PID
Datasheet OM402
Datasheet OM402
Datasheet OM402
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402
Katalogový list OM402PID
PDF
2014.2
Download
Datasheet OM402PID
Datasheet OM402
Datasheet OM402
Datasheet OM402
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402
Katalogový list OM402PID
PDF
2013.2
Download
Datasheet OM402
Datasheet OM402
Datasheet OM402
Datasheet OM402PID
Datasheet OM402PID
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402
PDF
2012.2
Download
Datasheet OM402
Datasheet OM402
Datasheet OM402
Datasheet OM402PID
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402
PDF
2010.1
Download
Datasheet OM402
Datasheet OM402
Katalogový list OM402
PDF
2008.1
Download
Datasheet OM402
Katalogový list OM402
PDF
2006.2
Download
Datasheet OM402PID
Katalogový list OM402PID
PDF
2023.1
Download
Datasheet OM402PID
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402PID
PDF
2020.1
Download
Datasheet OM402PID
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402PID
PDF
2019.1
Download
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402PID
PDF
2017.1
Download
Datasheet OM402PID
Datasheet OM402PID
Datasheet OM402PID
Katalogový list OM402PID
PDF
2014.1
Download
Datasheet OM402PID
PDF
2013.1 ru Download
Datasheet OM402PID
PDF
2012.1 c Download
Katalogový list OM402
PDF
2009.1 cs Download
Katalogový list OM402
PDF
2007.1 cs Download
Katalogový list OM402PID
PDF
2016.1 cs Download
Show all ↓ Hide ↑

Firmware

File name File type Version Language Download
OM 402PID-1 78-002
HEX
2019 xx Download
Show all ↓ Hide ↑

Software

File name File type Version Language Download
GSD OM-Profibus
GSD OM-Profibus
ZIP
2020
Download
GSDML OM-Profinet
ZIP
2020.2.33 xx Download
Show all ↓ Hide ↑

CAD

File name File type Version Language Download
OM box
DWG
2014 xx Download
Show all ↓ Hide ↑

ISOLATED TRANSDUCER • USB < > OM INSTRUMENTS

Small compact transducer OM LINK USB with cable ensures safe and comfortable galvanically isolated connection between your computer and ORBIT MERRET instruments.