OMD 202UQC
4/6 digit UNIVERSAL COUNTER
The OMD 202 model series are large programmable displays designed for indoor and outdoor use with IP64 cover.
Type OMD 202UQC is a universal 6-digit panel programmable two-channel counter/frequency meter/signal evaluation from IRC sensors, and timer/clock. The instrument is based on a single-chip microcontroller and efficient gate array, which ensures high accuracy, stability and easy operation of the instrument.
Displays are suitable for projection of measured data in production lines and operations with legibility up to 80 m.
-
4/6 digit programmqable projection
-
counter/frequency meter/timer/clock
-
0,002 Hz…1 MHz; UP/DW; IRC
-
three-color LED or high bright LED
-
digit height: 57; 100; 125 mm
-
IR control
-
tare/preset/sum/math.funkctions
-
digital filters, imput filters
-
size of DIN 96 x 48 mm
-
power supply 10…30 V AC/DC or 80…250 V AC/DC
Options
-
excitation
-
comparators
-
data output
-
analog output
Input
UQC
Input
menu selectable
on contact, TTL, NPN/PNP, Line
0...60 V, comparation levels are adjustable in the menu
on contact, TTL, NPN/PNP, Line
0...60 V, comparation levels are adjustable in the menu
Input frequency
0,002 Hz…1 MHz
0,002 Hz…500 kHz (Mode QUADR and UP/DW)
0,002 Hz…500 kHz (Mode QUADR and UP/DW)
Measurement mode
| SINGLE | Counter/Frequency |
| A + B | Counter/Frequency with AND function |
| xNOR | Counter/Frequency with NOR function |
| STRIDA | Duty cycle measurement |
| QUADR | Counter/Frequency for IRC sensor |
| UP/DW | Counter/Frequency |
| UP - DW | Counter/Frequency |
| TIME | Stopwatch |
| RTC | Clock |
Time base
0,05/1/2/3/5/10/20 s
1/2/5/10 min
1/2/5/10 min
Calibration coefficient
0,00001…999999
Preset
0…999999
Input filter
out
1/10/100/250/500/1 000 kHz
1/10/45/55/65/100 Hz
2/5/10 s
1/10 min
1/10/100/250/500/1 000 kHz
1/10/45/55/65/100 Hz
2/5/10 s
1/10 min
Functions
| Preset | initial non-zero value, which is always read after resetting the instrument |
| Current value | single setting of the initial value |
| Summation | registration of numbers during shift operation |
External inputs
Number
3 inputs, on contact
Functions
| OFF | No function |
| HOLD | Stopping measurement (option: Display - Analog output - Limits) |
| TARA | Tare activation |
| CLEAR | Resetting display |
| SUMA | Sum display |
| CL.SUM. | Resetting sum |
| NUL. M.M. | Resetting Min/Max. value |
Projection
Display range
-999…9999, 3-coloured 7-segment LED
-99999…999999, 3-coloured 7-segment LED
-999…9999, single-coloured intensive LED (1200 mcd)
-99999…999999, single-coloured intensive LED (1200 mcd)
-99999…999999, 3-coloured 7-segment LED
-999…9999, single-coloured intensive LED (1200 mcd)
-99999…999999, single-coloured intensive LED (1200 mcd)
Number of characters
4 characters (only for height 100/125 mm
6 characters
6 characters
Display height
57 mm, 100 mm, 125 mm
Display colour
red, green, red/green/orange
Signalizing LED
| 1, 2, 3, 4 | Limits L1, L2, L3, L4 (red) |
| T | Tare (green) |
| M | Min./Max. value (green) |
Description
the last two digits of the display can be used to display measured variables (only 6-digit display)
Decimal point
menu adjustable - fixed or floating
Display brightness
menu adjustable
Displayed values
| COUNT. | Value from channel Counter |
| FREQ. | Value from channel Frequency |
Settings
Control
The instrument is set and controlled by an IR remote control
Selected functions can also be controlled via external inputs
Selected functions can also be controlled via external inputs
Menu
| LIGHT | contains only items necessary for basic device settings with password access |
| PROFI | Full device settings with password access |
| USER | User menu of any item, selected from LIGHT/PROFI. Access without password. |
Optional functions
Buttons "Left", "Up", "Down", "Enter" can be assigned additional optional features
| ZAKAZ | button has no function |
| COUNT. | Viewing value - channel Counter |
| FREQ. | Viewing value - channel Frequency |
| CLEAR | Counter reset |
| TARE | Activating function Tare |
| CL. SUM. | Summation reset |
| SUM. | Viewing Summation |
| NUL. TA. | Tare reset |
| MENU | Direct access to the selected menu item |
| DOC. H. | Temporary projection of selected values |
| START | Start for Stopwatch/watch |
| PAUZA | Till the next touch the display will show the last value |
| CLR | Resetting Stopwatch/Watch |
| STOP | Stopping Stopwatch/Watch |
| CLR. ST. | Stopping and resetting Stopwatch/Watch |
OM Link
Company communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instruments
OM Link program is also designed for visualization and filing of meas. values from more instruments
Instrument accuracy and functionality
Temperature coefficient
50 ppm/°C
Accuracy
±0,01 % of range + 1 digit (frequency)
Overload capacity
2x; 10x (t < 30 ms)
Linearization
linear interpolation in 50 points (only via OM Link)
Digital filters
| arithmetic mean | from 2…100 measurements |
| floating mean | from 2…30 measurements |
| exponential mean | from 2…100 measurements |
| rounding | setting projection step for display |
| input filter | transmits input signal range 1 MHz...10 min |
Functions
| Tare | designed to reset display on non-zero input signal |
| Min/max value | registration of min./max. value achieved during measurement |
| Peak value | display shows only max. or min. values |
| Preset | initial non-zero value, which is read after each counter reset |
| Summation | number registration upon shift operation |
| Current value | single setting of the initial value |
Math. functions
polynom, 1/x, logarithm, exponential, power, root, sin x
Time backup
Lithium cell CR 2032RV, 3V/220 mAh
Watch-dog
reset after 400 ms
Calibration
at 25°C and 40 % r.h.
Comparators
Type
Digital, menu adjustable, contact connect. < 30 ms
Mode
| Hysteresis | switch. point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) determ. switching delay |
| From-To | output interval ON and OFF |
| Dose | period, its multiples and time (0 ... 99.9 s), during which the output is active |
Output
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
3x relay, switch on contact (250 VAC/30 VDC, 3A)
4x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
3x relay, switch on contact (250 VAC/30 VDC, 3A)
4x relay, switch on contact (250 VAC/30 VDC, 3A)
Analogue outputs
Type
Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
Temperature coefficient
15 ppm/°C
Nonlinearity
±0,1 % of range
Rate
response to value change < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V, 1 000 Ohm/24 V
Error state
at range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruption
error message indication (<3.0 mA)
Detection of current loop interruption
Data outputs
Protocol
ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
Data format
8 bits + no parity + 1 stop bit (ASCII)
7 bits + even parity + 1 stop bit (Messbus)
7 bits + even parity + 1 stop bit (Messbus)
Rate
600…230 400 Baud
0,0096…12 MBaud (PROFIBUS)
0,0096…12 MBaud (PROFIBUS)
RS 232
isolated
RS 485
isolated, addressing max. 31 instruments
Sensor excitation
Adjustable
5…24 VDC/max. 1,2 W
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 45 A/2 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 45 A/2 ms, isolated
Current draw
< 22 W/22 VA
Power supply protection
Power supply is protected by a fuse inside the instrument
Mechanical properties
Dimensions
| 57 mm/6 d. | 375 x 119 x 88 mm |
| 100 mm/4 d. | 465 x 181 x 88 mm |
| 100 mm/6 d. | 651 x 181 x 88 mm |
| 125 mm/4 d. | 539 x 237 x 88 mm |
| 125 mm/6 d. | 754 x 237 x 88 mm |
Panel cutout
| 57 mm/6 d. | 367 x 111 mm |
| 57 mm/6 d. | 367 x 111 mm |
| 100 mm/6 d. | 643 x 173 mm |
| 125 mm/4 d. | 531 x 228 mm |
| 125 mm/6 d. | 746 x 228 mm |
Material
Anodized aluminum, black
Installation
Into panel
On the wall/ceiling using bracket (included)
On the wall/ceiling using bracket (included)
Operating conditions
Connection
cable bushings
connector terminal board, cable section < 1,5/2,5 mm2
connector terminal board, cable section < 1,5/2,5 mm2
Stabilization period
within 15 minutes after switch on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64
El. safety
EN 61010-1, A2
Dielectric strength
4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. output
Insulation resistance
for polution degree II, measuring cat. III.
| power supply | 670 V (ZI), 300 V (Di)* |
| input, output, PN | 300 V (ZI), 150 V (Di)* |
EMC
EN 61326-1
Datasheets
User manuals
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
man0100_OMProfi_2020.3_en.pdf
man0100_OMProfi_2020.3_cs.pdf
|
PDF
|
2020.3 |
|
Download |
|
man01_OMD202UQC_2018.4.0_en.pdf
man01_OMD202UQC_2018.4.0_cs.pdf
|
PDF
|
2018.4.0 |
|
Download |
|
man0101_OMProfibus_a2014.2.1_en.pdf
man0101_OMProfibus_a2014.2.1_cs.pdf
|
PDF
|
2014.2.1 |
|
Download |
| man0101_OMProfibus_a2014.2.0_cs.pdf |
PDF
|
2014.2.0 | cs | Download |
|
man0102_OMProfibus_a2010.1.2_en.pdf
man0102_OMProfibus_a2010.1.2_cs.pdf
|
PDF
|
2010.1.2 |
|
Download |
| man0102_OMProfibus_a2007.1.0_cs.pdf |
PDF
|
2007.1.0 | cs | Download |
| man0102_OMProfibus_a2010.1.1_en.pdf |
PDF
|
2010.1.1 | en | Download |
|
man04_OMD202UQC_a2012.3.1_en.pdf
man04_OMD202UQC_a2012.3.1_cs.pdf
|
PDF
|
2012.3.1 |
|
Download |
|
man05_OMD202UQC_a2011.3.1_en.pdf
man05_OMD202UQC_a2011.3.1_cs.pdf
man05_OMD202UQC_4D_2011.3.1_cs.pdf
|
PDF
|
2011.3.1 |
|
Download |
| man05_OMD202UQC_a2011.3.0_cs.pdf |
PDF
|
2011.3.0 | cs | Download |
Application notes
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
an05_Modbus commands OMD 202UQC_2012_en.xls
an05_Modbus prikazy OMD 202UQC_2012_cs.xls
|
XLS
|
2012 |
|
Download |
|
an05_Modbus commands OMD 202UQC-4_2013_en.xls
an05_Modbus prikazy OMD 202UQC-4_2013_cs.xls
|
XLS
|
2013 |
|
Download |
| an05_protokol MODBUS popis_2021.01_cs.pdf |
PDF
|
2021.01 | cs | Download |
| an05_Protocol MODBUS description_2006.01_en.pdf |
PDF
|
2006.01 | en | Download |
Certificates
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
|
crt02_EU_Declaration_OMD202_2022_en.pdf
crt02_EU_Prohlaseni_OMD202_2022_cs.pdf
|
PDF
|
2022 |
|
Download |
|
crt03_Declaration_17050_OMD202_2022_en.pdf
crt03_Prohlaseni_17050_OMD202_2022_cs.pdf
|
PDF
|
2022 |
|
Download |
Firmware
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
| fw01_OMD202UQC-4 80-003 OMD_2013_xx.hex |
HEX
|
2013 | xx | Download |
Software
| File name | File type | Version | Language | Download |
|---|---|---|---|---|
| sw03_GSD OM-Profibus_2020_xx.zip |
ZIP
|
2020 | xx | Download |
| sw04_GSDML OM-Profinet_2020.2.33_xx.zip |
ZIP
|
2020.2.33 | xx | Download |
| sw05_GSDML OM-Profinet_2024.2.33_xx.zip |
ZIP
|